Power-intensive operations demand equipment that can perform reliably without compromise. The JA750 Genset is engineered to support mission-critical environments where continuous electricity is fundamental to safety, productivity, and operational efficiency. Equipped with a high-performance Perkins engine, this generator delivers dependable power while maintaining the durability required for long operating cycles.

The JA750 is well suited for major manufacturing facilities, commercial towers, hospitals, industrial processing plants, and large-scale infrastructure developments. JNA complements every installation with expert engineering guidance, professional installation services, and reliable nationwide support, ensuring customers receive a complete power solution tailored to their operational needs. Complete technical specifications and performance details can be found in the section below.

COMPLETE TECHNICAL INFORMATION

JA 750

Specification

JA 750

Specification

PRIMARY POWER SPECIFICATIONS

Prime Power (PRP) kVA

750 kVA

Rated Speed (RPM)

1500 RPM

Prime Power (PRP) kW

600 kW

Output Voltage (V)

230/400 V

Standby Power (LTP) kVA

825 kVA

Frequency

50 Hz

Standby Power (LTP) kW

660 kW

__

__

ENGINE & MECHANICAL DETAILS

Engine Brand

Perkins

Bore x Stroke (mm)

145 mm x 183 mm

Engine Model

2806A-E18TTAG5

Compression Ratio

14.5:1

Aspiration Type

Turbocharged, air to air aftercooled

Governor Type

Electronic

Number of Cylinders

6

Starting Motor Capacity

N/A

Displacement (Liters)

18.1 L

Max. Exhaust Temperature

580 °C (Standby)

Max. Exhaust Back Pressure

N/A

__

__

ALTERNATOR, FLUIDS & CONTROL SYSTEMS

Fuel Consumption @ 100% Load

154 L/h

Oil Capacity (Liters)

62.0 L

Fuel Consumption @ 75% Load

115 L/h

Fuel Tank Capacity (Liters)

Separate Tank as required

Fuel Consumption @ 50% Load

81 L/h

Coolant Capacity (Liters)

61.0 L

Specification Category

Technical Parameter

JA 750

PRIMARY POWER SPECIFICATIONS

Prime Power (PRP) kVA

Prime Power (PRP) kW

Standby Power (LTP) kVA

Standby Power (LTP) kW

Rated Speed (RPM)

Output Voltage (V)

Frequency

750 kVA

600 kW

825 kVA

660 kW

1500 RPM

230/400V

50 Hz

ENGINE & MECHANICAL DETAILS

Engine Brand

Engine Model

Aspiration Type

Number of Cylinders

Displacement (Liters)

Bore x Stroke (mm)

Compression Ratio

Governor Type

Starting Motor Capacity

Max. Exhaust Temperature

Max. Exhaust Back Pressure

Perkins

2806A-E18TTAG5

Turbocharged, air to air aftercooled

6

18.1 L

145 mm x 183 mm

14.5:1

Electronic

N/A

580 °C (Standby)

N/A

ALTERNATOR, FLUIDS & CONTROL SYSTEMS

Fuel Consumption @ 100% Load

Fuel Consumption @ 75% Load

Fuel Consumption @ 50% Load

Oil Capacity (Liters)

Fuel Tank Capacity (Liters)

Coolant Capacity (Liters)

154 L/h

115 L/h

81 L/h

62.0 L

Separate Tank as required