Skip to main content

JNA

JA200 – Cummins 200 kVA Generator

BRIEF

Power reliability is a critical requirement for facilities operating under demanding commercial and industrial conditions. The JA200 Genset is engineered to deliver dependable standby and prime power, helping businesses maintain productivity when grid power becomes unreliable. Built around Cummins’ globally trusted engine platform, this generator provides the durability, load-handling capability, and operational stability required for continuous business operations.

The JA200 is an excellent choice for manufacturing plants, hospitals, commercial developments, logistics facilities, processing units, and infrastructure projects that rely on uninterrupted electrical supply. Backed by JNA’s engineering expertise, every generator is professionally installed, commissioned, and supported with responsive after-sales service across Pakistan. Detailed technical specifications and generator configuration are available below to help you select the right solution for your operational requirements.

COMPLETE TECHNICAL INFORMATION

JA 200

Specification

JA 200

Specification

PRIMARY POWER SPECIFICATIONS

Prime Power (PRP) kVA

200 kVA

Rated Speed (RPM)

1500 RPM

Prime Power (PRP) kW

160 kW

Output Voltage (V)

230/400 V

Standby Power (LTP) kVA

220 kVA

Frequency

50 Hz

Standby Power (LTP) kW

176 kW

__

__

ENGINE & MECHANICAL DETAILS

Engine Brand

Cummins

Bore x Stroke (mm)

114 mm x 135 mm

Engine Model

6CTAA8.3-G2

Compression Ratio

18.0:1

Aspiration Type

Turbocharged, Charged Air Cooled

Governor Type

Electronic

Number of Cylinders

6

Starting Motor Capacity

N/A

Displacement (Liters)

8.3 L

Max. Exhaust Temperature

510 °C (Prime) / 580 °C (Standby)

Max. Exhaust Back Pressure

N/A

__

__

ALTERNATOR, FLUIDS & CONTROL SYSTEMS

Fuel Consumption @ 100% Load

45 L/hr

Oil Capacity (Liters)

23.8 Ltr

Fuel Consumption @ 75% Load

34 L/hr

Fuel Tank Capacity (Liters)

450 Ltrs

Fuel Consumption @ 50% Load

23 L/hr

Coolant Capacity (Liters)

34.0 Ltr

Specification Category

Technical Parameter

JA 200

PRIMARY POWER SPECIFICATIONS

Prime Power (PRP) kVA

Prime Power (PRP) kW

Standby Power (LTP) kVA

Standby Power (LTP) kW

Rated Speed (RPM)

Output Voltage (V)

Frequency

200 kVA

160 kW

220 kVA

176 kW

1500 RPM

230/400V

50 Hz

ENGINE & MECHANICAL DETAILS

Engine Brand

Engine Model

Aspiration Type

Number of Cylinders

Displacement (Liters)

Bore x Stroke (mm)

Compression Ratio

Governor Type

Starting Motor Capacity

Max. Exhaust Temperature

Max. Exhaust Back Pressure

Cummins

6CTAA8.3-G2

Turbocharged, Charged Air Cooled

6

8.3 L

114 mm x 135 mm

18.0:1

Electronic

N/A

510 °C (Prime) / 580 °C (Standby)

N/A

ALTERNATOR, FLUIDS & CONTROL SYSTEMS

Fuel Consumption @ 100% Load

Fuel Consumption @ 75% Load

Fuel Consumption @ 50% Load

Oil Capacity (Liters)

Fuel Tank Capacity (Liters)

Coolant Capacity (Liters)

45 L/hr

34 L/hr

23 L/hr

23.8 Ltr

450 Ltrs

34.0 Ltr