Skip to main content

JNA

JA45 – Isuzu 45 kVA Generator

BRIEF

The JA45 Genset is engineered for businesses that require reliable power support to maintain productivity during utility disruptions. Combining the proven performance of an Isuzu engine with JNA’s engineering expertise, this generator is built to deliver stable electrical output for commercial environments where operational continuity is a priority. Its efficient design makes it suitable for routine standby applications while helping optimize long-term operating costs.

From commercial buildings and warehouses to medical facilities, schools, and light industrial operations, the JA45 offers the versatility needed across a wide range of sectors. JNA delivers every Isuzu JA45 with professional installation, commissioning, and responsive technical support to ensure dependable performance throughout its service life. The detailed technical sheet below provides comprehensive information on the generator’s specifications, configuration, and operational capabilities.

COMPLETE TECHNICAL INFORMATION

J45

Specification

J45

Specification

PRIMARY POWER SPECIFICATIONS

Prime Power (PRP) kVA

45 KVA

Rated Speed (RPM)

1500

Prime Power (PRP) kW

38 kW

Output Voltage (V)

400/230 V

Standby Power (LTP) kVA

50 KVA

Frequency

50 Hz

Standby Power (LTP) kW

42 kW

__

__

ENGINE & MECHANICAL DETAILS

Engine Brand

ISUZU

Bore x Stroke (mm)

93*102 mm

Engine Model

JE 493ZL DB-02

Compression Ratio

18.2:1

Aspiration Type

Intercooler Turbo

Governor Type

Mechanical

Number of Cylinders

4 in line

Starting Motor Capacity

12 V/2.8 kW

Displacement (Liters)

2.77 L

Max. Exhaust Temperature

< 500 °C

Max. Exhaust Back Pressure

15 KPA

__

__

ALTERNATOR, FLUIDS & CONTROL SYSTEMS

Fuel Consumption @ 100% Load

6.5 L/h

Oil Capacity (Liters)

5.6 L

Fuel Consumption @ 75% Load

4.7 L/h

Fuel Tank Capacity (Liters)

80 L

Fuel Consumption @ 50% Load

3.1 L/h

Coolant Capacity (Liters)

4.5 L – 5 L

Specification Category

Technical Parameter

JA 45

PRIMARY POWER SPECIFICATIONS

Prime Power (PRP) kVA

Prime Power (PRP) kW

Standby Power (LTP) kVA

Standby Power (LTP) kW

Rated Speed (RPM)

Output Voltage (V)

Frequency

45 KVA

38 kW

50 KVA

42 kW

1500 

400/230 V

50 Hz

ENGINE & MECHANICAL DETAILS

Engine Brand

Engine Model

Aspiration Type

Number of Cylinders

Displacement (Liters)

Bore x Stroke (mm)

Compression Ratio

Governor Type

Starting Motor Capacity

Max. Exhaust Temperature

Max. Exhaust Temperature

ISUZU

JE 493ZL DB-02

Intercooler Turbo

4 in line

2.77 L
93*102 mm

18.2:1

Mechanical

12 V/2.8 kW

< 500 °C

15 KPA

ALTERNATOR, FLUIDS & CONTROL SYSTEMS

Fuel Consumption @ 100% Load

Fuel Consumption @ 75% Load

Fuel Consumption @ 50% Load

Oil Capacity (Liters)

Fuel Tank Capacity (Liters)

Coolant Capacity (Liters)

6.5 L/h

4.7 L/h

3.1 L/h

5.6 L

80 L

4.5 L – 5 L