The JA1000 Genset is built to meet the demands of facilities where uninterrupted power is essential for operational success. Combining Perkins’ globally recognized engine technology with JNA’s engineering expertise, this high-capacity generator delivers dependable electrical performance for organizations operating in challenging commercial and industrial environments.

Ideal for large production facilities, hospitals, commercial infrastructure, data centers, airports, and major construction projects, the JA1000 offers the reliability required to support mission-critical operations. JNA ensures every installation is backed by professional commissioning, technical consultation, and responsive after-sales service, giving customers confidence throughout the generator’s operational lifecycle. Complete technical specifications and performance information are available below.

COMPLETE TECHNICAL INFORMATION

JA 1000

Specification

JA 1000

Specification

PRIMARY POWER SPECIFICATIONS

Prime Power (PRP) kVA

1000 kVA

Rated Speed (RPM)

1500 RPM

Prime Power (PRP) kW

800 kW

Output Voltage (V)

230/400 V

Standby Power (LTP) kVA

1100 kVA

Frequency

50 Hz

Standby Power (LTP) kW

880 kW

__

__

ENGINE & MECHANICAL DETAILS

Engine Brand

Perkins

Bore x Stroke (mm)

160 mm x 190 mm

Engine Model

4008TAG2A

Compression Ratio

13.6:1

Aspiration Type

Turbocharged, air to air charge cooled

Governor Type

Electronic (ISO 3046-4 A1)

Number of Cylinders

8

Starting Motor Capacity

N/A

Displacement (Liters)

30.6 L

Max. Exhaust Temperature

465 °C (Standby)

Max. Exhaust Back Pressure

N/A

__

__

ALTERNATOR, FLUIDS & CONTROL SYSTEMS

Fuel Consumption @ 100% Load

240 L/h

Oil Capacity (Liters)

153 L

Fuel Consumption @ 75% Load

162 L/h

Fuel Tank Capacity (Liters)

Separate Tank as required

Fuel Consumption @ 50% Load

111 L/h

Coolant Capacity (Liters)

149 L

Specification Category

Technical Parameter

JA 1000

PRIMARY POWER SPECIFICATIONS

Prime Power (PRP) kVA

Prime Power (PRP) kW

Standby Power (LTP) kVA

Standby Power (LTP) kW

Rated Speed (RPM)

Output Voltage (V)

Frequency

1000 kVA

800 kW

1100 kVA

880 kW

1500 RPM

230/400V

50 Hz

ENGINE & MECHANICAL DETAILS

Engine Brand

Engine Model

Aspiration Type

Number of Cylinders

Displacement (Liters)

Bore x Stroke (mm)

Compression Ratio

Governor Type

Starting Motor Capacity

Max. Exhaust Temperature

Max. Exhaust Back Pressure

Perkins

4008TAG2A

Turbocharged, air to air charge cooled

8

30.6 L

160 mm x 190 mm

13.6:1

Electronic (ISO 3046-4 A1)

N/A

465 °C (Standby)

N/A

ALTERNATOR, FLUIDS & CONTROL SYSTEMS

Fuel Consumption @ 100% Load

Fuel Consumption @ 75% Load

Fuel Consumption @ 50% Load

Oil Capacity (Liters)

Fuel Tank Capacity (Liters)

Coolant Capacity (Liters)

240 L/h

162 L/h

111 L/h

153 L

Separate Tank as required